Water vapor transmission rate tester ISO 2528, ASTM E96, ASTM D1653
Model: BZ-WVTRStandards GB/T 1037, GB/T 16928, ISO 2528, ASTM E96, ASTM D1653, TAPPI T464,DIN 53122-1,JIS Z0208,YBB 00092003 This water vapor transmission rate tester is suitable for measuring the water vapor transmission rate of plastic films, composite films and other films, sheet materials, and medical and building materials. The test is based on the cup method. Features Weighing method test principle, intermittent weighing that meets the requirements of the standards, the system is automatically cleared before each measurement to ensure the unity and accuracy of the data High-definition LCD touch screen, more intuitive in sight and easier operation One sample is tested in a single test, the process is fully automated, the lifting and weighing of the moisture permeable cup is controlled by the cylinder, and the data is accurate and reliable Innovative circulating dehumidification system, built-in vacuum pump, effectively prevent the formation of humidity gradient above the moisture permeable cup, ensure accurate test Wide range, high precision, automatic temperature and humidity control, meeting various test conditions. Test results support multi-format storage and data output, including test report Excel, cloud sharing Provide standard weight quick calibration mode, weighing system to ensure the accuracy of test data Complies with the third-level authority of GMP users Can carry out single and group statistical analysis of test results With ISP online control and upgrade functions, the test function can be changed remotely as required Special computer communication software, real-time display of test, data analysis and processing, data storage.
Specifications
Model BZ-WVTR-01 BZ-WVTR-04 Test Range 0.01 ~ 10,000 g/m2 ·24h(normal) 0.1 ~ 10,000 g/m2 ·24h(normal)(Customizable weight gain mode) Number of samples 1pc(Single cavity) 1 ~ 4 (Independent data)(can customize ≤8) Test accuracy 0.01 g/m2 ·24h 0.01 g/m2 ·24h System resolution 0.0001 g 0.0001 g Test temperature 15°C ~ 65°C(normal) 10°C ~ 55°C(normal) Temperature control accuracy ±0.5°C ±0.5°C Test humidity 10%RH ~ 98%RH(standard 90%RH) 10%RH ~ 90%RH Humidity control accuracy ±1%RH ±2%RH Blowing wind speed 0.5 ~ 2.5 m/s (Non-standard optional) 0.5 ~ 2.5 m/s (optional) Test area 33.18 cm2 33.18 cm2 Specimen thickness ≤ 3 mm (other thickness can be tailor made) ≤ 3 mm(Other thickness requirements can be customized) Specimen size Φ74 mm Φ72 mm Connection size Ф6 mm PU tube Ф6 mm PU Dimensions 440 mm (L) × 450 mm (W) × 450 mm (H) 500 mm (L) × 500 mm (W) × 550 mm (H) power supply AC 220V 50Hz AC 220V 50Hz net weight 42 kg 42 kg
Configurations
Host, professional software, breathable cup, gas drying device, automatic drying filter, test weight, communication cable, sampler, quantitative dropper, gloves
Options: standard membrane, air compressor, drying container, 4A molecular sieve
Remarks: The air source inlet of this machine is Ф6mm polyurethane tube; the air source and distilled water are provided by the user
Related Items