Civil engineering & Material Testing equipments

Carbon /Hydrogen /Nitrogen in coal analyzer

It is applicable to determine the content of carbon, hydrogen and nitrogen in solid materials such as coal and coke. 

Features

◎ 39 samples can be set out at one time, and 78 samples can be purchased at one time. The instrument can automatically send samples, set samples, and conduct cyclic testing. The whole process does not require manual operation after setting out, and samples can be added, subtracted, and replaced at any time during the analysis process;

◎ The horizontal structure is adopted, and the instrument can be placed on the laboratory table, which is convenient for customers to operate;

◎ The advanced PID algorithm is used to control the temperature, the furnace temperature control accuracy can reach ± 1 ℃, and the temperature control accuracy of the thermostatic chamber and the air tank can reach ± 0.1 ℃;

◎ The absolute pressure sensor is used to monitor the pressure of the whole gas path of the instrument, which can automatically detect the air tightness of the whole gas path and the furnace, infrared pool, thermal conductivity pool, and gas storage tank;

◎ The instrument adopts infrared spectrum absorption method to determine carbon content and hydrogen content, and thermal conductivity method to determine nitrogen content;

◎ Fast test speed, high degree of automation, and the time for testing carbon, hydrogen and nitrogen is about 4 minutes;

◎ During the experiment, the option of “automatic cooling after the experiment” can be selected. After the experiment is completed, the computer will automatically shut down and the instrument will automatically cool down. No one can be on duty. No personnel are required to manually cool down and shut down after the test is completed;

◎ The experimental report can be prepared according to the customer’s requirements to reduce the customer’s workload;

◎ It can be connected to the laboratory management system to ensure that the balance data does not fall to the ground, and the test results are backed up and uploaded.

Specifications

ModelMJ-EC-CHNMJ-EC-CHMJ-EC-HMJ-EC-HM
Measure rangeC:0.005%~100%,H:0.01%~60%,N:0.008%~60%C:0.005%~100%, H: 0.01%~60%H:0.01%~60%H:0.01%~20%
Method   Infrared spectral absorption thermal conductivity methodInfrared spectral absorptionInfrared spectral absorptionCoulomb method
RepeatabilityC(Cad≤0.5%),H(Had≤0.15%),N(Nad≤0.08%)C(Cad≤0.5%),H(Had≤0.15%)H(Had≤0.15%)H(Had≤0.15%)
AccuracyWithin the uncertainty range of the standard sampleWithin the uncertainty range of the standard sampleWithin the uncertainty range of the standard sampleWithin the uncertainty range of the standard sample
Temp. rangeRT+10~1050℃, ±1℃RT+10~1050℃, ±1℃RT+10~1050℃, ±1℃RT+10~850℃, ±1℃
Sample quantityRecommend 80~100mgRecommend 80~100mgRecommend 80~100mg70±5mg
Sample feedingAutomaticAutomaticAutomaticManual
Sample quanatity39 Pieces/batch, add/replace samples during the test, and purchase 78 sample trays for one-time setting out39 Pieces/batch, add/replace samples during the test, and purchase 78 sample trays for one-time setting out39 Pieces/batch, add/replace samples during the test, and purchase 78 sample trays for one-time setting out1
Single sample process time4min4min4min8-15mins
Carrier gasHelium, purity ≥ 99.995%, pressure 0.25 ± 0.1MPaHelium, purity ≥ 99.995%, pressure 0.25 ± 0.1MPaHelium, purity ≥ 99.995%, pressure 0.25 ± 0.1MPa/
Auxiliary gasOxygen, purity ≥ 99.5% when measuring hydrocarbon element, purity ≥ 99.995% when measuring nitrogen element, pressure 0.25 ± 0.1MPaOxygen, purity ≥ 99.5% when measuring hydrocarbon element, purity ≥ 99.995% when measuring nitrogen element, pressure 0.25 ± 0.1MPaOxygen, purity ≥ 99.5% when measuring hydrocarbon element, purity ≥ 99.995% when measuring nitrogen element, pressure 0.25 ± 0.1MPaOxygen purity≥99.5%
Power gasInert gas, no oil, no water, pressure 0.29±0.1MPaInert gas, no oil, no water, pressure 0.29±0.1MPaInert gas, no oil, no water, pressure 0.29±0.1MPa/
Power≤4.5kw≤4.5kw≤4.5kw≤4.5kw
Power supply220VAC±10%, 50HZ220VAC±10%, 50HZ220VAC±10%, 50HZ220VAC±10%, 50HZ
TypeHorizontal (can be placed on table)Horizontal (can be placed on table)Horizontal (can be placed on table)Horizontal
Overall dimensions(mm)690×740×720690×740×720690×740×720920×470×440
Net wight(kg)10510210247