Civil engineering & Material Testing equipments

Microcoulometric method sulfur and chlorine analyzer for light petroleum

sulfur and chlorine analyzer for light petroleum

The microcoulometric sulfur and chlorine analyzer adopting the microcoulometric analysis technology to determine the content of sulfur and chlorine in the sample.

Model: SY-0253

Standards: GB/T11061-1997,GB/T18612-2011 SY/T7508-1997,ASTMD3120,ASTMD3246, SH/T0253-1992,SH/T0222-1992

The sample is oxidized into titratable ions through a cracking furnace using the oxidation method, and then titrated in a titration cell. The sulfur content is calculated based on the amount of electricity consumed during the electrolytic titration process and Faraday’s law. The microcoulometric sulfur chlorine analyzer is suitable for light petroleum products with a boiling point of 40-310C. Samples with sulfur content ranging from 0.5 to 1000ppm and samples with sulfur content greater than 1000ppm should be diluted and measured. This instrument can also measure the content of chlorine.

Characteristics of sulfur and chlorine analyzer for light petroleum

1. Direct human-machine dialogue, easy to operate.

2. The computer controls the entire analysis, data processing, and other processes, displays the working status of the entire process, and can save or print parameters and results as needed.

3. Adopting international popular circuits and imported components, reducing instrument noise and improving detection sensitivity

4. It has the characteristics of stable and reliable performance, easy operation, high analysis accuracy, and good repeatability.

Technical parameter of sulfur and chlorine analyzer for light petroleum

Bias voltage range: 0-500mv

Measurement range: 0.1~10000ng/u1

Temperature control range: room temperature~1000C

Temperature control accuracy: ± 1C

Measurement accuracy:

Sample concentration (ng/u1) 0.2RSD (%) 35

Sample concentration (ng/ μ 1) 1.0 RSD (%) 10

Sample concentration (ng/u1) 100RSD (%) 5

Sample concentration (ng/ μ 1) 1000RSD (%) 2

Gas source requirements: common nitrogen and common oxygen

Power supply voltage: AC 220V ± 10% 50Hz ± 10%

Power: 3.5KW

Overall dimensions:

Host: 410X350X75 (mm)

Temperature control: 530X420X360 (mm)

Mixer: 290X270X360 (mm)

Sampler: 350X130X140 (mm)

Have any question, Please enter the form below and click the submit button.


*
*
1 + 9 = ?
Please enter the answer to the sum & Click Submit to verify your registration.
CATEGORY AND TAGS:

Oil test Instruments

Related Items

Verified by MonsterInsights